載入中...請稍候...

Temperature control 12V DC fan speed controller

  • 圖片 1
價格:
paul@advancepanda.com
品牌:
條件:
存貨量:
1000
Bookmark and Share


產品介紹

Description:

This speed controller supports all fans within 12V 5A. Synchronous rectification mode output, high efficiency. Even if the high current does not require additional radiator. Multiple fans can be used in parallel (the total current is not more than 5A), which supports automatic temperature control and manual speed regulation. Temperature control speed with 4 temperature zones can be set, is convenient for all kinds of application environment. With open three line fan monitoring function (turn off alarm)

 

Specifications:

Parameter

Value

Circuit board size

(L*W*H)50mm*49mm*15mm,
(Location of positioning hole)44mm*43mm,
(Diameter) 3.2mm

Power supply voltage

DC12V (It can work safely between 9-14V,Do not be used in automobiles)

Power supply current

According to the total current of the fan, the power consumption of the board is less than 0.1A

 

Output regulation range 

0%-100% of power supply voltage (can be shut down )

Temperature control temperature range error

according to the temperature probe error, general 2-5% (small probe temperature error within 1-2 Celsius)

Maximum continuous output current

5A

Maximum peak output current

7A (3 minutes)

Efficiency

93% (12V input 8V 4A output state test)

Turn off alarm speed threshold

450+-50rpm (for 2 pole signal fan ‚)

 

1>. When the manual adjustment voltage is very low or 0V, it is equivalent to shutting down the fan. Suppose the temperature control is running on the basis of shutting down. The output voltage increases linearly with the increase of temperature due to the accelerating temperature, while the fan needs to be operated at least 3-5V voltage. Therefore, the actual accelerating temperature (or referred to as the starting temperature) after shutting down the fan is higher than the acceleration temperature in the setting temperature zone. However, this may cause the fan to start and stop frequently when the heat source is small, leading to the high temperature of the heat source component. Careful use.
2>. More than 97% of the common fans are 2 pole signal fan. There are also 3 pole signal and 4 pole signal fans (rarely seen). For the 2 pole signal, if it is below 450 turns alarm. For the 3 pole signal fan, it is equivalent to less than 300 turn alarm.

 

Setting instructions:
(to be effective once each set is recharged):
1>. Temperature setting: set as follows:

TP1

TP2

Acceleration temperature

Full speed temperature

OFF

OFF

35 Celsius

45 Celsius

ON

OFF

40 Celsius

55 Celsius

OFF

ON

50 Celsius

70 Celsius

ON

ON

60 Celsius

90 Celsius

 

2>. Stop alarm setting:
When the setting switch 3 is in the on position, the alarm function is turned on to stop the switch. Please monitor the three wire fan to find the position of the three wire fan pin in the middle of the output. When the fan speed is lower than the threshold, the alarm will be stopped until the fan speed is resumed. Please switch the switch to OFF (non ON) without stopping the alarm function.